The Integre Pro™ is the first all-in-one laser/slit lamp photocoagulator to offer customized configuration of yellow, red and green wavelengths – choose the configuration which best meets your clinical requirements in order to maximize treatment flexibility. This advanced photocoagulator platform starts by improving your vision: the Integre Pro™ integrates the treatment laser in the diagnostic slit lamp to deliver a high-resolution image with a wider peripheral view and optimum illumination of the fundus.
Available 2012.
Better Diagnosis and Treatment All in One
The purpose-built Integre Pro™ slit lamp provides high-precision optics matched for optimum laser performance – creating the industry’s leading system for the diagnosis and treatment of retinal disease. Featuring a 10-degree stereoscopic angle, the Integre Pro™ provides better depth perception and a wider peripheral view, combined with high-contrast imaging and optimal illumination of the fundus. In addition, the system’s True Spot™ optical system offers a uniform, sharp-edged top-hat beam on the retina with the added benefit of low power density at the cornea.

Designed to Maximize Your Workflow
The Integre Pro’s all-in-one laser/slit lamp design provides you with additional working space – making it easier to align the patient and to position the contact lens. It also offers the added benefit of convenient access to the ambidextrous laser controls and allows you to perform treatment without disturbing your view of the treatment area.
Unlike other photocoagulator and multi-color laser systems, which require an external dichroic or fixed mirror in order to connect the laser to the slit lamp, the Integre Pro™ integrates the laser delivery optics inside the slit lamp, ensuring the laser beam is perfectly coaxial with your line of vision. This provides better visualization and optimal illumination.
In addition, this integration of the treatment laser with the diagnostic slit lamp minimizes system downtime, because there are no exposed fiber-optic or electrical cables to accidentally damage. It also eliminates the need for you to calibrate the system, or to reposition cables or adapters – simply aim, shoot and fire.

Greater Efficiency at the Touch of a Button
The Integre Pro’s yellow-red and green-red wavelength configurations deliver the full treatment spectrum of traditional multi-color lasers – and all at the touch of a button. Switch easily between wavelengths for seamless retinal treatments, allowing you to perform multiple procedures in one setting: target localized pathologies with short laser shots, homogeneously distribute the laser energy over a large area for controlled applications in single shot mode, or quickly and efficiently apply the laser energy in repeat mode.
Fundamentally BetterDesigned to make photocoagulation procedures as efficient as possible, the Integre Pro™ incorporates a unique single pump, solid-state dual-mode laser cavity design. This innovative cavity design provides stable, high-power output for the most demanding of ophthalmic procedures.
Control at Your Fingertips
The Integre Pro™ features a high-precision micromanipulator that allows you to accurately perform grid treatments near the macula, whilst exquisite titration control offers optimal flexibility and accuracy when treating in areas of varied retinal pigmentation.
Maximize Your Investment
The Integre Pro™ is an affordable alternative to the traditional multi-color laser. It also has an upgrade path to the yellow-red and green-red configurations, enabling you to add an additional wavelength as your practice and clinical requirements grow.
561nm Yellow: maximal absorption in hemoglobin with zero or negligible absorption in macular xanthophyll.
The 561nm yellow wavelength creates a more predictable, controlled burn than 514/532nm green wavelengths. This results in low scotoma formation, which provides for better control over the laser-tissue interaction. Because it approximates the peak absorption of hemoglobin, but it is not highly absorbed by melanin in the retinal pigment epithelium (RPE) or xanthophyll in the neurosensory retina, 561nm yellow is ideal for treatments in and around the macula. It also produces less scatter, which means superior transmission through existing opacities. In addition, treatment is more efficient at lower energy levels, creating significantly less discomfort for the patient during and following treatment. 561nm yellow is also suitable for performing all 514/532nm green laser procedures, including iridotomies and laser trabeculoplasty.
670nm Red: deep penetration for effective treatment of choroidal vessels
The 670nm wavelength features low absorption of hemoglobin, improving its transmission through minor preretinal, subretinal or intraretinal hemorrhage. Its penetration depth is ideal for selectively treating choroidal vessels, without coagulation of retinal vessels. 670nm also offers less scatter than the yellow wavelength, making it ideal for transmission through a cloudy cornea or lens. The results are gentle, deep retinal tissue penetration and effective treatment of choroidal vessels.
532nm Green: the standard of care for common procedures like retinal photocoagulation, laser trabeculoplasty and iridotomy.
The 532nm wavelength is primarily absorbed by melanin cells, and is therefore ideally suited for a number of treatment applications in and around the retinal pigment epithelium (RPE) region, including pan-retinal photocoagulation (PRP).
Downloads
| Product Specifications |
| Laser Source |
solid state laser diode and cavity |
| Wavelengths |
red: 670 nm, yellow: 561 nm, green: 532 nm |
| Power at the Fiber Port |
red: ≥ 1.35 watts, yellow: ≥ 2 watts, green: ≥ 2 watts |
| Power at the Cornea |
red: 1 watt, yellow: 1.5 watts, green: 1.5 watts |
| Exposure Time |
0.01 to 8.0 seconds |
| Spot Size |
50 to 1000 μm, continuously variable |
| Repeat Mode |
up to 20 hertz |
| Aiming Beam |
red 635 nm, adjustable intensity |
| Micromanipulator |
ambidextrous, vibration damped |
| Magnification |
6x, 10x, 16x, 25x, 40x |
| Cooling |
air cooled |
| Electrical Requirements |
100-240 VAC, 50/60 Hz, 800 VA |
| Weight |
35kg, 77 lbs. (laser only) |
| Dimensions (HxWxD) |
62 x 76 x 47 cm, 24 x 30 x 19 inches (laser only) |
| Standard Accessories |
footswitch, remote control, safety glasses, laser safety sign, dust cover, motorized eye safety filter |
| Optional Accessories |
Total Solution™ tables, LIO, beam splitter, co-observation tube, 35mm camera adapter, video camera adapter, transport cases, photocoagulation laser lenses, tonometer mount, Power Control™ footswitch |
*Specifications are subject to change without notice.
|
Total Solution™ Tables (optional accessory)
Ellex Total Solution™ tables are designed to meet the needs of any environment - with the added benefit of comfort, flexibility and an optimized patient-surgeon interface. The following tables are available in the Total Solution™ range:
- Wheelchair Accessible
- Wheelchair Accessible, Mobile
- Mobile
|



|
|
Power Control™ Footswitch (optional accessory)
Adjust critical treatment parameters while maintaining hands-on control of the slit lamp - without disturbing your view of the retina.
|
 |
|
Laser Indirect Ophthalmoscope (LIO) (optional acccessory)
This lightweight-design LIO is based on the Heine Omega 180 binocular indirect ophthalmoscope, with coaxial laser beam and illumination.
|
 |
|
High-Visibility Eye Safety Filter
Provides full protection without obstructing treatment view. Can be set to move in and out of position with every shot, or in fixed position whenever the laser is in ready mode.
|
|
| Back-Lit Remote Control |
|
|
Beam Splitter
|
|
|
Co-Observation Tube
|
|
|
35mm Camera Adapter
|
|
|
Video Camera Adapter
|
|
|
Transport Cases
|
|
|
Photocoagulation Laser Lenses
|
|
|
Tonometer Mount
|
|
|
Motorized Safety Filter
|
|
|